Assist Control ventilation - Neonatal Disorders


What is Assist Control Ventilation?

Assist Control Ventilation (ACV) is a mode of mechanical ventilation commonly used in neonates with respiratory distress. ACV ensures that the infant receives a set number of breaths per minute with a predetermined volume or pressure. This mode is highly supportive for neonates who have underdeveloped lungs or are suffering from severe respiratory disorders.

Indications for Use in Neonates

ACV is typically indicated for neonates with conditions such as Respiratory Distress Syndrome (RDS), Bronchopulmonary Dysplasia (BPD), and severe Hypoxic-Ischemic Encephalopathy (HIE). These conditions often result in compromised lung function, making it difficult for the infant to breathe independently.

How Does ACV Work?

In ACV, the ventilator delivers a breath every time the neonate initiates one, ensuring effective ventilation even if the baby’s effort is weak. If the neonate fails to initiate a breath within a specified time, the ventilator will provide a mandatory breath. This dual mechanism helps in maintaining consistent oxygenation and carbon dioxide removal.

Benefits of ACV in Neonates

The primary benefit of ACV is that it reduces the work of breathing, allowing the neonate’s respiratory muscles to rest. This is particularly beneficial for premature infants whose respiratory systems are not fully developed. Additionally, ACV helps in maintaining stable blood gases, reducing the risk of complications like intraventricular hemorrhage (IVH) and retinopathy of prematurity (ROP).

Risks and Complications

While ACV offers numerous benefits, it also comes with potential risks. Over-ventilation can lead to barotrauma or volutrauma, which can damage the delicate lung tissues. There is also a risk of pneumothorax, a condition where air leaks into the space between the lung and chest wall, causing the lung to collapse. Close monitoring is essential to mitigate these risks.

Monitoring and Adjustments

Continuous monitoring of the neonate’s respiratory parameters is crucial while on ACV. Parameters such as tidal volume, respiratory rate, and oxygen saturation need to be regularly evaluated. Adjustments to the ventilator settings may be necessary based on the neonate’s evolving clinical condition to ensure optimal respiratory support.

Weaning from ACV

Weaning a neonate off ACV requires a gradual reduction in the ventilatory support as the infant’s respiratory function improves. This process involves lowering the mandatory breath rate and encouraging spontaneous breathing. Successful weaning is a significant milestone indicating improved lung function and overall health of the neonate.

Conclusion

Assist Control Ventilation plays a crucial role in managing neonates with severe respiratory conditions. It provides essential respiratory support, allowing time for the neonate’s lungs to heal and grow. However, careful monitoring and timely adjustments are imperative to minimize risks and ensure the best possible outcomes for these vulnerable patients.